NS0-093 Sample Questions

NS0-093 Sample Questions & Answers

Troubleshooting, from basic multi-protocol issues to storage system recovery, carries the most weight, alongside clustered Data ONTAP architecture with NFS, CIFS and SAN access, aggregates and FlexVols, monitoring and quota management, and what's new in ONTAP 9.0.

Launch the full NS0-093 simulator →

Showing 10 of 20 free samples.

  1. Question 1Advanced

    Data Access Protocols and Management · NFS Security Configuration

    A support engineer must configure an export-policy rule for an NFSv4.1 export that enforces Kerberos 5p (krb5p) security for all client access. The policy should deny access to any client not using krb5p. Which configuration is correct?

    Show answer & explanation

    Correct answer: C

    To enforce a specific Kerberos security level, the -rorule, -rwrule, and -superuser parameters must all be set to the desired level, in this case, krb5p. This ensures that read, write, and root access are all protected with encryption and integrity checking. Setting the protocol to nfs covers all versions, and the client match 0.0.0.0/0 applies the rule to all clients.

  2. Question 2Beginner

    Troubleshooting Techniques · Maintenance Mode Commands

    A support engineer has booted a node into maintenance mode to troubleshoot a boot failure. To verify the contents of the boot device, the engineer needs to list the directories at the root of the file system. Which command should be used?

    ls /________

    Show answer & explanation

    Correct answer: B

    In maintenance mode, the boot device's root file system is mounted under /mnt. Therefore, to see directories like /etc, /dev, etc., on the boot media, the engineer must list the contents of /mnt.

  3. Question 3Advanced

    Advanced Features and New Enhancements in ONTAP 9.0 · Hardware Maintenance

    During routine maintenance on a FAS8700 controller, an amber fault light illuminates on the NVMEM/NVRAM battery. The controller is part of an active HA pair and must not be taken offline. What is the correct high-level procedure to replace the battery non-disruptively?

    Show answer & explanation

    Correct answer: A

    Even though some components are hot-swappable, the NVMEM/NVRAM battery is not. It is a critical component for protecting in-flight data. The correct non-disruptive procedure in an HA pair is to perform a takeover, which moves all services to the partner node. Then, the affected controller can be safely halted and powered down for the battery replacement. Once the hardware service is complete, the node is booted, and a giveback operation returns its services.

  4. Question 4IntermediateSelect 2

    Monitoring, Manageability, and Performance · AutoSupport Analysis

    A support engineer is analyzing an AutoSupport bundle to diagnose the root cause of a system panic that generated a kernel core dump. The panic string references a memory parity error. Which TWO sections of the AutoSupport bundle are most critical for this investigation? (Select TWO).

    Show answer & explanation

    Correct answers: A, C

    The MESSAGES.GZ file contains the system log files, which include the panic message, stack trace, and events leading up to the panic. This is essential for understanding the context of the failure.

    The SYSCORE file is the compressed core dump itself. A deep analysis of this file using debugging tools is required to determine the exact instruction and memory address that caused the parity error and subsequent panic.

  5. Question 5Intermediate

    Troubleshooting Techniques · RAID Failure Scenarios

    A disk in a 12-drive RAID-TEC aggregate fails and is replaced. During the subsequent RAID reconstruction process, a second disk within the same RAID group also fails. What will be the resulting state of the aggregate?

    Show answer & explanation

    Correct answer: B

    RAID-TEC (Triple Erasure Coding) is designed to withstand up to three simultaneous disk failures within a RAID group. The failure of a second disk during reconstruction will put the aggregate into a degraded state, but it will remain online and accessible. The reconstruction process will continue using the parity information from the remaining disks.

  6. Question 6Beginner

    Introduction to NetApp Storage System Architecture and Components · Cluster Interconnect Cabling

    When deploying a two-node switchless cluster using the onboard cluster interconnect ports on an AFF C-series platform, what is the correct physical cabling configuration?

    Show answer & explanation

    Correct answer: C

    For a two-node switchless cluster, redundancy is achieved by directly connecting the corresponding cluster interconnect ports on each node. Port e0a on the first node connects to port e0a on the second, and port e0b on the first connects to port e0b on the second, creating two independent, parallel links.

  7. Question 7Advanced

    Monitoring, Manageability, and Performance · SMB Performance Troubleshooting

    A manufacturing company uses a NetApp cluster for storing large design files accessed via SMB. Users report that file transfers are significantly slower than expected. A support engineer is brought in to diagnose the issue. The cluster is connected to the corporate network via a 2-port 10GbE LACP interface group.

    The engineer runs cifs top -sort-key open_files and observes that a single user session from a backup server has thousands of files open, consuming a large number of CIFS sessions. Network monitoring on the cluster shows that the LACP interface group is not exceeding 50% of its total capacity, and latency is low.

    Based on this information, what is the most logical next step for the support engineer to take?

    Show answer & explanation

    Correct answer: B

    The cifs top output is the key piece of evidence. It points to a specific client (the backup server) consuming an excessive number of resources (open files/sessions). Since the network is not saturated, the bottleneck is likely related to how this single client is interacting with the CIFS server, potentially hitting session limits or causing processing delays on the controller that affect other users. Investigating the backup application's behavior is the correct next step.

  8. Question 8Intermediate

    Troubleshooting Techniques · POST Error Resolution

    After a field engineer replaces the system board on a FAS2750 node, the system fails to boot into ONTAP. The console displays a POST error message indicating a 'System ID Mismatch'. What is the first corrective action the engineer must perform from the boot loader prompt?

    Show answer & explanation

    Correct answer: B

    A 'System ID Mismatch' error occurs because the unique identifier of the new system board (FRU) does not match the System ID that was associated with this ONTAP installation (stored on the boot media/disks). The engineer must use the setenv command at the boot loader prompt to update the new board's System ID to match the old one, allowing ONTAP to recognize the system and boot correctly.

  9. Question 9Intermediate

    Data Access Protocols and Management · iSCSI MPIO Troubleshooting

    A customer is configuring iSCSI access from a Windows Server to a NetApp LUN and has installed the Host Utilities Kit. After configuring the iSCSI initiator on the server and mapping the LUN to the correct igroup on the SVM, the administrator can only see a single path to the LUN in Disk Management, even though multiple data LIFs exist on the SVM. What is the most common misconfiguration on the ONTAP SVM that would cause this issue?

    Show answer & explanation

    Correct answer: D

    For iSCSI MPIO to function correctly, the host initiator must be able to discover all available paths. ONTAP uses selective LUN mapping (SLM) and reports only the paths that are part of the SVM's iSCSI target portal group. If the administrator created multiple data LIFs but did not add them all to the portal group for that SVM, the host will only discover and report the single path that is advertised.

  10. Question 10Intermediate

    Introduction to NetApp Storage System Architecture and Components · MetroCluster Operations

    True or False: In a MetroCluster configuration, the RDB (Replicated Database) service must be running and healthy on both clusters for a negotiated switchover to be successful.

    Show answer & explanation

    Correct answer: A

    This statement is true. The RDB contains critical configuration information for the cluster. During a negotiated (planned) switchover, the clusters must communicate to ensure a consistent and graceful transfer of services. A healthy and synchronized RDB on both sites is a prerequisite for this process to succeed.

Ready for the real thing?

The full NS0-093 simulator has every exam-style question, timed mode, and instant scoring.